Low
cost, high reliability |
|
|
High
efficiency, low working temp. |
|
|
Built
in EMI filter, low ripple noise |
|
|
Compact
size, light weight |
|
|
|
100%
full load burn-in test |
|
|
Short
circuit/over load protection |
|
|
International
AC input selected |
|
 |
|
Type
No
|
Output
|
Tol.
|
R&N
|
Effi.
|
EM-150-5 |
5V,
20A |
±2% |
100mV |
78% |
EM-150-7.5 |
7.5V,
20A |
±1% |
150mV |
80% |
EM-150-12 |
12V,
12.5A |
±1% |
180mV |
82% |
|
EM-150-15
|
15V,10A
|
¡Ó1%
|
180mV
|
84%
|
|
EM-150-24
|
24V,6.5A
|
¡Ó1%
|
240mV
|
85%
|
|
EM-150-48
|
48V,
3.2A
|
¡Ó1%
|
240mV
|
87%
|
| Input
voltage |
90~132VAC/180~264VAC
selected by SW. |
| Input
frequency |
47
- 63Hz |
| Inrush
current |
Cold
start, 35A/115V & 230VAC |
| Output
voltage |
Refer
to below table(¡Ó10% ADJ.) |
| Overload
protection |
105%~150%
output shutdown |
| Over
voltage protection |
115%~135%
of output voltage(EM-150-24: 125%~145%) |
| Setup,
rise, hold up time |
100ms, 50ms, 20ms |
| Withstand
voltage |
I/P-O/P:3KV,I/P-FG:1.5KV,
1min. |
|
Working
temp
|
0-30¢J@100%,
50¢J@100% with cooling fan, -10%¢J@80%
(15V~48V: 0-50¢J@100%, 60¢J@60%) |
| Safety
standard |
UL
1012 , UL 1950, TUV EN60950 |
| EMC
standard |
EN55022 class B, EN61000-4-2,3,4,5,6,8,11 EN60555-3-2,3 |
| Connection |
7P
/ 9.5mm pitch terminal block |
|
|
|
|
|
|